AMBATTUR, CHENNAI
+916309384196

'steam staurated'

Items tagged with 'steam staurated'

product image
VORTEXFLOWMETER

IBR VORTEX OMEGA FLOWMETER The Vortex flow meter, manufactured by Pride Controls & Systems Pvt Ltd, has received approval from the Indian Boiler Regulation (IBR) for measuring steam in boiler applications. These flow meters provide valuable data for assessing the performance of the system, calculating boiler efficiency, and monitoring steam consumption. In some instances, they also furnish a measurement signal for the boiler control system. The Pride Vortex Flow meter operates on the Karman vortex street principle and is suitable for measuring liquids, gases, and steam across a diverse range of industries, including petroleum, chemical, metallurgy, and heat supply. It is available for steam applications with pressure and temperature compensation, providing a reliable and accurate measurement for evaluating system performance.

Send Message
product image
VORTEXFLOWMETER

IBR VORTEX OMEGA FLOWMETER The Vortex flow meter, manufactured by Pride Controls & Systems Pvt Ltd, has received approval from the Indian Boiler Regulation (IBR) for measuring steam in boiler applications. These flow meters provide valuable data for assessing the performance of the system, calculating boiler efficiency, and monitoring steam consumption. In some instances, they also furnish a measurement signal for the boiler control system. The Pride Vortex Flow meter operates on the Karman vortex street principle and is suitable for measuring liquids, gases, and steam across a diverse range of industries, including petroleum, chemical, metallurgy, and heat supply. It is available for steam applications with pressure and temperature compensation, providing a reliable and accurate measurement for evaluating system performance.

Send Message
product image
VORTEX FLOWMETER

PRIDE - Ω500H VORTEX FLOW METER WITH IBR CERTIFICATION The Vortex flow meter, manufactured by Pride Controls & Systems Pvt Ltd, has received approval from the Indian Boiler Regulation (IBR) for measuring steam in boiler applications. These flow meters provide valuable data for assessing the performance of the system, calculating boiler efficiency, and monitoring steam consumption. In some instances, they also furnish a measurement signal for the boiler control system. The Pride Vortex Flowmeter operates on the Karman vortex street principle and is suitable for measuring liquids, gases, and steam across a diverse range of industries, including petroleum, chemical, metallurgy, and heat supply. It is available for steam applications with pressure and temperature compensation, providing a reliable and accurate measurement for evaluating system performance.

Send Message
product image

Pride Controls & Systems is pleased to offer the orifice plate flow meter is a crucial differential pressure flow meter used extensively for measuring clean liquid, gas, and steam mass flow. It is universally applicable for all pipe sizes and offers a highly cost-effective solution for assessing fluid flows in larger pipes (exceeding 6" diameter). Predominantly composed of stainless steel, the orifice plate is the most prevalent material employed. When it comes to low flow rate measurement, a d/p cell featuring an integral orifice is unequivocally the optimal choice. It is imperative to note that orifice plate flow meters are exclusively recommended for clean, single-phase fluids. Even minimal build-up can result in substantial measurement inaccuracies or unit blockage. During installation, critical factors, including tap location and condition, pipe state, adequacy of straight pipe runs, gasket interference, pipe, and orifice bore misalignment, and lead line design must be meticulously observed. Moreover, potential adverse circumstances such as the blunting of the sharp edge, corrosion or erosion-induced nicks, plate warpage stemming from water hammer and dirt, and the deposition of grease or secondary phases on the orifice surface necessitate unwavering attention.

Send Message
product image
VORTEX FLOWMETER

Pride Vortex Flowmeter which is used to Measure Conductive and Non-Conductive Liquids, Dry Gas, Wet Gas, Mixture of Gas, Saturated and Superheated Steam. A Vortex flowmeter measures the fluid flow when an obstruction Placed in a Fluids Steam, the vortices are shed Alternately from the Placed Obstruction. This Creates the Pattern of flow which is know as Karman Street effect Discovered by Todor Von Karman. The Shedding Frequency of the Fluid is Proportional to the Flow Velocity. These Vortex air flowmeters are designed to measure the mass flow and volumetric Flow of the above fluid's in Various applications which are not stable in Parameters like Conductivity, PH, Viscosity, Density, Specific Gravity, Pressure and Temperature.

Send Message
product image
VORTEX FLOWMETER

Pride Controls and Systems are the Manufacturer of high Performance Industrial grade Vortex flowmeters which is used to measure Conductive and Non-Conductive liquids, Dry Gas, Wet Gas, Mixture of Gases, Saturated and Superheated Steam. These Vortex air flowmeters are designed to measure the mass flow and volumetric Flow of the above fluid's in Various applications which are not stable in Parameters like Conductivity, PH, Viscosity, Density, Specific Gravity, Pressure and Temperature. The advantages of Vortex Flow meter are Easy installation, Non Moving parts and maintenance free design and High resistance to corrosion, pressure & Temperature. A Vortex flowmeter Measures the fluid flow when an Obstruction Placed in a fluid's Steam, the vortices are shed alternately from the placed Obstruction. These have the features of super Heated & Saturated steam measurement.

Send Message
product image
METAL TUBE ROTAMETER

Pride Controls & Systems Pvt Ltd is an ISO 9001 : 2015 Certified Manufacturing company of High Performance Industrial grade flow measuring instruments . The Pride PCMT-H Metal tube variable area flowmeter is to measure the flow rate of liquid, steam, gas and oil with greater flexibility & less pressure drop in various industrial applications. PRINCIPLE OF OPERATION OF VARIABLE AREA FLOW METER This Flowmeter works based on variable area principle. When the fluid flow increases, the float in a metal tube raises and the float’s height is directly proportional to the flow rate of the fluid..The higher the flow rate the higher the float is raised. The float moves in a tapered tube up or down in proportion to the flow rate of the fluid and the annular area between the float and the tube. Advantages of Metal tube Variable Area Flowmeter • Short mounting length and compact construction • Easy method of installation • No straight pipe run required before or after the flowmeter • Metallic tube with a robust construction • Indication by means of magnetic coupling • High performance even at extreme working conditions • High resistance to corrosion • Low pressure drop • Vertical or horizontal connections Features of Metal tube Variable Area Flowmeter • Installation: Vertical as standard and Horizontal Mounting can be done with optional feature • Display: LCD display for flow Tantalizer on request • Flow measurement: Suitable for Liquid, Steam, Gas, Air & Oil • Flow Units: LPH, M3/hr, Kg/hr, Nm3/hr • Line Sizes: 1/4th to 6” • Transmitter Output: 4 – 20 mA Analog output can be given as optional feature • Alarm Output: Relay Output • Pressure Rating: 40 Bar as standard and up to 200 Bar can be given on request • Temperature: 50 Deg C to +200 Deg C as standard and up to 400 Deg C on request • End Connections: Flanged, Threaded, Tri Clamp and others as per request • Body Material: SS304, SS316, SS316L, and other materials as per request • Wetted Parts: PTFE, SS316L, SS316, SS304, and other materials as per request.

Send Message

Still searching for
steam staurated?